Page: 28

Analysis Help
Analysis: Averaged trace amplitude vs W.F. level


Displacements measured for each frame, on the trace selected by the "Amplitude trace #", are displayed with respect to corresponding level measurements on the waveform selected by the "Amplitude W.F. #". The trace amplitude measurements are taken the same way they are for the "Raw trace amplitude vs step cycle" graph. The waveform amplitude measurements are taken the same way they are for the "Trace averaging based on W.F. level" analysis. The range of voltage levels measured from the selected waveform is divided evenly into a number of bins, and all displacements are added into these bins to obtain an average curve which is displayed.

Deleted frames, and frames whose tag values are not in the "Tag list" are excluded. You can also exclude frames that occur during the inactive phase of cycles, or the active phase, in the same way as for the "Trace averaging based on W.F. level" analysis, using the "Active cycle phase only" option.

The "Fixed W.F. level bins" option has the same effect here as it does for the "Trace averaging based on W.F. level" analysis, causing the "Min W.F. amplitude" and "Max W.F. amplitude" to define a fixed range which is divided into bins, even if it exceeds the range of levels in the waveform.

 

Key sequence  Parameter Initial Value
<Esc>AGTTA  Analysis method  Averaged trace amplitude vs W.F. level
<Esc>SF  Run file  ?
<Esc>SRS  Start of run  0 msec
<Esc>SRE  End of run  2.14748e_08 msec
<Esc>SRD  # of deleted sections  0
<Esc>SCID  Phase selection delay  0 msec
<Esc>SCIW  Phase selection window  0.1 msec
<Esc>SLTA  Active cycle phase only  N
<Esc>SCW  Cycle W.F. #  ?
<Esc>Wn<CR>SCV  Cycle crossings  ?
<Esc>SCS  Base cycles on stop time  N
<Esc>SCT  Base cycles on spike trains  N
<Esc>SLWN  Amplitude W.F. #  0
<Esc>SLWRL  Min W.F. amplitude  -80000 mV
<Esc>SLWRU  Max W.F. amplitude  79997.6 mV
<Esc>SLWF  Fixed W.F. level bins  N
<Esc>SLWD  W.F. amplitude delay  0 msec
<Esc>SLWW  W.F. amplitude window  0.1 msec
<Esc>ST  Tag list  All
<Esc>SLTN  Amplitude trace #  0
<Esc>SLTS  Trace amplitude point  ?
<Esc>SLTR  Trace amplitude ref  -0.1 msec
<Esc>SLTWS  Trace ampl. point window  0.1 msec
<Esc>SLTWR  Trace ampl. ref window  0.1 msec
<Esc>SLTWA  Average trace ampl. ref.  N
<Esc>SLTWD  Trace ampl. ref. regression degree  0
<Esc>SLTWF  Find max trace amplitude  Y
<Esc>SLTWI  Trace ampl. integration  N
<Esc>SLTWM  Average trace ampl. sample  N
<Esc>SGB  # bins- graph  100
<Esc>SLTP  Trace ampl. as % of max  N
<Esc>SLWP  W.F. ampl. as % of max  N
<Esc>SGR  Regression degree  0
<Esc>SDD  Graph description  ""
<Esc>SDM  Main graph title  ""
<Esc>SDGG  Graph type  Adaptive
<Esc>SDGH  Histogram type  Adaptive
<Esc>SDGS  Std. deviation type  Adaptive
<Esc>SDGD  Diamond symbol size  5
<Esc>SDGT  Graph tag symbol  ""
<Esc>SDSA  Auto scale  Y
<Esc>SDSR  Round out scale bars  Y
<Esc>SDSXS  X scale bars  Y
<Esc>SDSYS  Y scale bars  Y
<Esc>SDSXL  Min X  0
<Esc>SDSXU  Max X  0
<Esc>SDSYL  Min Y  0
<Esc>SDSYU  Max Y  0
<Esc>SDSYHL  Min Y- hist  0
<Esc>SDSYHU  Max Y- hist  0
<Esc>SDTA  Show areas under curves  N
<Esc>SDTH  Histogram display  N
<Esc>SDTI  Interpolation  Y
<Esc>SDTX  Extend interpolation  Y
<Esc>SDTS  Display std dev  N
<Esc>SDTT  Top title display  Y
<Esc>SDUL  Sample units  mV

 


SCRC WWW administrator: www@scrc.umanitoba.ca